MGE UPS SYSTEMS
 
Comet UPS Module
40 / 50 / 65 / 80 / 100 / 125 / 150 kVA

www.mgeups.com

About MGE

Tell Us What You Think?

Technical Support

Comet Brochure

Comet Facility Planning Data Sheet

Comet Guide Specification

Comet Installation and User Manual

Comet Installation Drawings

Comet GUI User Manual

 
 
  DRAWING LIBRARY (all drawings in PDF format)
 
UPS MODULE - 40-80 kVA
D90-160080-00 (E02)  UPS MODULE DESCRIPTION (40/50/65/80 kVA)
  1/7  UPS cabinet dimensions, center of gravity, air exhaust, maintenance access
  2/7  Bottom conduit plate installation instructions
 3/7  Top conduit plate installation instructions
  4/7  Front view covers removed (shows location of fuses and terminal blocks)
  5/7  Rear view of front door (control wire to battery cabinet, dry contact pinouts, air filter)
 6/7  Electrical specifications, heat rejection and weight
  7/7  Wye connection
D90-160080-05 (B01) Auxiliary Cabinet
D90-160080-06 (B01) Distribution Cabinet (All kVA)
D90-160080-10 (D02) UPS $ Battery Cabinet (40-80 kVA)
D90-160080-14 (A02) System Installation with External Maintenance Bypass (40-80 kVA)
D90-160080-15 (C02) System Installation with Auxiliary Cabinet (40-80 kVA)
D90-160080-16 (C02) System Installation with Distribution (40-80 kVA)
D90-160080-17 (A02) System Installation with Auxiliary Cabinet (600V)
D90-160080-18 (A02) System Installation with Distribution (600V)
D90-160080-20 (B00) Cabinet Attachment & Seismic Zone 4 Bracing
85-163091-00   (A01) Seismic Bracket Installation
100-150 kVA UPS INSTALLATION
D90-160150-00 (C02) UPS Cabinet Installation 480/480V 
D90-160151-01 (A01) System Installation 480/480V
D90-160151-10 (A01) System Installation 480/208V 
D90-160151-13 (A02) System Installation 480/208V with Distribution
D90-160151-20 (A01) System Installation 208/208V with Auxiliary Cabinet (Auto Input Transformer) - also includes 220/220V & 600/208V Versions
D90-160151-21 (A01) System Installation with Auxiliary Cabinet
D90-160151-22 (A02) System Installation with Distribution
D90-160151-24 (A01) System Installation Dual Input with Two Auto Transformers in the Auxiliary Cabinet (208/208, 220/220, 600/208)
D90-160151-25 (A02) System Installation Dual Input with Two Auto Transformers in the Auxiliary Cabinet & Distribution (208/208, 600/208)
D90-160151-26 (A01) System Installation with Maintenance Bypass (100-150 kVA) (208/208)
D90-160151-32 (A01) System Installation 600/600V with Two Auxiliary Cabinets for Transformers
D90-160151-34 (A01) System Installation Dual Input 600/600V with Two Auxiliary Cabinets for Transformers
D90-160151-39 (A01) System Installation Dual Input 480/480-277V with Output Transformer/Neutral
D90-160151-40  (A01) System Installation
D90-160153-00  (A00) Auxiliary Cabinet Installation
COMMunicationS & CONTROL WIRING
D90-160080-00 (E01) Control Wiring Between UPS and Battery Cabinets (5/7)
D90-160080-00 (E01) DB15 UPS Manager Dry Contact Communications (5/7)
See Communications Manuals for information about other communications devices
BATTERY CABINET - 26" & 32"
D90-160080-03 (C01) Battery Cabinets (26" & 32" for all kVA)
BATTERY CABINET - 48"
D90-160152-00 (C01) Installation - Large Battery Cabinets
71-163854-00   (A00) Seismic Bracket for 48" Battery Cabinet
Maintenance Bypass Cabinet - MATCHING
D90-160080-50 (A00) Stand Alone Cabinet  80A-300A
D90-160080-51 (A00) Stand Alone Cabinet  450A-600A
D90-160080-52 (A01) System Installation 40-80 kVA MBC 480
D90-160080-53 (A01) System Installation 40-80 kVA MBC 480-208V
D90-160080-54 (A01) System Installation 40-80 kVA MBC 208V
D90-160151-52 (A01) System Installation 100-150 kVA MBC 480V
D90-160151-53 (A01) System Installation 100-150 kVA MBC480-280V
D90-160151-54 (A01) System Installation 100-150 kVA MBC 208V
Maintenance Bypass Cabinet - wall mount
D90-160042-00 (A02) 2 Circuit Breaker Maintenance Bypass 
D90-160043-00 (A02) 3 Circuit Breaker Maintenance Bypass
BATTERY DISCONNECT CABINET - wall mount
D90-166000-02 (A00) 225A Battery Disconnect (50/65/80 kVA)
D90-166000-04 (A00) 400A Battery Disconnect (100/125/150 kVA)
remote alarm panels - SURFACE MOUNT
d90-133129-00 (B00) Remote Alarm Status Panel (RASP)
d90-133058-00 (B00) Remote Summary Alarm Panel (RSAP)
 
top of page
 
(c) 2005 MGE UPS SYSTEMS
 
Acrobat reader is required. Click to download..