DRAWING LIBRARY
(all drawings in PDF format) |
| |
|
Single Module UPS |
D90-135051-XX
(X0) Installation Drawing Table |
|
|
D90-135051-00
(X9) Single Module Installation Drawing |
D90-135051-02
(X1)
Single Module, Maintenance Bypass Cabinet |
D90-135051-03
(X0) Single Module, Top Entry, Critical Bus Synch |
D90-135051-04
(X0) Single Module, Top Entry, Maintenance Bypass Cabinet, Critical
Bus Synch |
D90-135051-06
(X0) Single Module, Bottom Entry |
D90-135051-07
(X0) Single Module, Bottom Entry, Maintenance Bypass Cabinet |
D90-135051-08
(X0) Single Module, Bottom Entry, Critical Bus Synch |
D90-135051-09
(X0) Single Module, Bottom Entry, Maintenance Bypass Cabinet, Critical
Bus Synch |
D90-135052-00
(X0) Single Module Installation Drawing |
|
|
|
Parallel Module UPS |
D90-135051-01
(X2) Parallel Module Installation Drawing |
D90-135052-01
(X0) Parallel Module Installation Drawing |
D90-135051-05
(X0) Parallel Module, Bottom Entry |
|
|
|
Battery Cabinet |
DM
Battery Cabinet with Standard Trays |
MGEDM-24012V-480-6-6D-A,
Standard Tray (01) |
MGEDM-20012V-480-5-5D-A,
Standard Tray (01) |
|
|
SM
Battery Cabinet with Roll Out Trays |
MGESM-20012V-480-5-5D-A-MECH-ILS,
Roll Out Tray (01) |
MGESM-24012V-480-6-6D-A-MECH-ILS,
Roll Out Tray (01) |
|
|
|
|
|
Battery Disconnect |
D90-135265-00
(X0) Battery
Disconnect, End, 2500A |
D90-135265-01
(X0) Battery
Disconnect, Mid, 2500A |
|
|
|
Maintenance Bypass Cabinet - Attached |
D90-135053-00
(X2) Attached Maintenance Bypass Cabinet |
D90-135053-01
(X0) Remote Maintenance Bypass Cabinet |
|
|
|
|
|
Remote Alarm Panels, Surface Mount |
D90-130141-00
(A01) Remote Summary Alarm Panel (RSAP) |
D90-130142-00
(E00) Remote Alarm Status Panel (RASP) |
|
|
|
Seismic Brackets |
D90-132252-99
(A00) Seismic Brackets |
D90-134453-01
(A00) Seismic Brackets |
| |
|
Critical Bus Synchronization
Module |
|
D90-132112-00
CBS Installation Drawing
|
|
|
|
Graphical Command Center (GCC), GUI Interface |
|
GRAPHICAL USER INTERFACE: All Multi-Module systems are equipped
with a single GCC (Graphical Command Center) located in the System
Static Switch Cabinet. The GCC monitors both system status and
individual module status. It is also equipped with an Ethernet port
that when connected to a network will allow the GCC to be remotely
viewed using a standard browser (2003 models and later only).
Graphical
Command Center
Manual
Graphical
Command Center
Brochure (Color)
Graphical
Command Center
Brochure
(Black/White)
The standard EPS 8000 is
equipped with 12 dry contacts (see installation drawing for details)
as well as a single serial port that can be configured for either
RS485 or RS232. Consult TSG for register maps for the serial
port. Also an additional two serial ports can be added using the
COMM+2 (GT2Z) option. If any Ethernet connectivity is required for
Network Based Power Management the Multislot expander can be
added to accommodate SNMP communications cards.
|
| |
|
System Static Switch Cabinet - Parallel
Systems |
|
SSC: The EPS
8000 can be paralleled for capacity or redundancy with up six modules
or a total capacity of 4000A using a System Static Switch Cabinet (SSC).
Consult the Configuration Team or your Power Systems Manager for SSC pricing,
features, and descriptions. |